In these Regulations—
effective dose means the sum of the weighted equivalent doses in all the tissues and organs of the body and is determined by the formula—
E = w T H T
T
where |
E is the effective dose, |
---|---|
|
W T is the tissue weighting factor for tissue or organ T , |
and |
H T is the equivalent dose in tissue or organ T ; |
equivalent dose means the absorbed dose averaged over a tissue or organ modified by the radiation weighting factor, W R and is determined by the formula—
H T = w R D T, R
R
where |
H T is the equivalent dose in tissue or organ T, |
and |
D T,R is the absorbed dose averaged over the tissue or organ T, due to radiation R; |
"medical exposure" means—
(a) the receipt of a radiation dose by a patient during the course of, or for the purposes of, a diagnosis or treatment of an injury or illness of the patient; or
(b) an exposure of a person to an emission of radiation (other than occupational exposure) knowingly incurred by that person while supporting and comforting a patient receiving a radiation dose during the course of, or for the purposes of a diagnosis or treatment of, an injury or illness of the patient; or
(c) the receipt of a radiation dose by a volunteer during the course of medical research;
"occupational exposure" means the exposure to an emission of radiation of a person using a radiation source or directly conducting a radiation practice;
"public exposure" means the exposure of a person to an emission of radiation that is not occupational exposure or medical exposure;
"the Act" means the Radiation Act 2005 .